Cardiac Device Manufacturing Glossary
100 terms total — 24 showing — Last updated 15 Sep 2026
NASPE/BPEG code
A five-letter coding system used to describe pacemaker programming and functionality.
device advisory
Official communication from device manufacturers to physicians regarding potential safety issues or performance concerns...
device pocket erosion
Breakdown of tissue overlying an implanted cardiac device, potentially exposing the device or leads.
device recall
Regulatory action requiring manufacturer notification and potential device replacement due to safety or performance issu...
device-device interaction
Electromagnetic interference between multiple implanted devices affecting function, requiring special consideration in m...
DF-1 connector
Industry-standard high-voltage connector for defibrillation leads, larger than IS-1 connectors to handle shock delivery.
elective replacement indicator
A device status indicating battery depletion has reached the point where replacement should be scheduled within several...
electromagnetic interference
External electromagnetic fields that can disrupt cardiac device function, requiring specific design considerations and p...
endocardial lead
A transvenous cardiac lead positioned inside the heart chambers, in contact with the endocardium.
endocardial pacing threshold
The minimum electrical energy required to consistently capture the heart muscle through an endocardial lead placed insid...
epicardial lead
A pacing lead attached to the outer surface of the heart muscle rather than inserted through blood vessels.
epicardial mapping
Electrophysiological technique mapping cardiac electrical activity from the heart's outer surface, used in CRT lead plac...
exit block
Failure of a paced stimulus to depolarize cardiac tissue despite adequate electrical output from the device.
far-field sensing
Detection of cardiac electrical activity from a chamber other than where the sensing electrode is located, potentially c...
generator longevity
Expected operational lifespan of the pulse generator battery, critical for patient counseling and replacement planning d...
header block
The connector assembly of a pulse generator where leads are inserted and secured with set screws.
hermetic seal integrity
The maintenance of a completely airtight and moisture-proof barrier in cardiac device enclosures to protect internal ele...
His-bundle pacing
A physiologic pacing technique that directly stimulates the heart's natural conduction system at the His bundle.
HRS consensus statement
Official guidance documents from the Heart Rhythm Society providing clinical recommendations for cardiac device manageme...
ICD
A device that monitors heart rhythm and delivers electrical shocks to correct life-threatening arrhythmias.
IDE study
A clinical study conducted under FDA authorization to evaluate an investigational medical device for safety and effectiv...
inappropriate shock
Delivery of defibrillation therapy by an ICD for rhythms that do not warrant defibrillation treatment.
insulation failure
Breakdown of the outer coating of a cardiac lead, causing electrical leakage and circuit malfunction.
interrogation
The process of wirelessly communicating with an implanted cardiac device to retrieve stored data and assess function.
IS-1 connector
The international standard connector design for cardiac pacing leads, featuring a 3.2mm diameter.