Cardiac Device Manufacturing Glossary
100 terms total — 24 showing — Last updated 15 Sep 2026
NASPE/BPEG code
A five-letter coding system used to describe pacemaker programming and functionality.
active fixation
A lead attachment mechanism using a retractable helical screw to anchor the electrode to cardiac tissue.
antitachycardia pacing
A low-energy ICD therapy that uses rapid pacing pulses to terminate ventricular tachycardia without delivering a shock.
arrhythmia burden
Percentage of time a patient experiences specific arrhythmias, as measured and calculated by cardiac device diagnostics.
ATP efficacy
Success rate of antitachycardia pacing in terminating ventricular tachycardia without requiring high-voltage shock thera...
atrial high-rate episode
Detected period of rapid atrial rhythm above programmed detection thresholds, stored by device diagnostics for clinical...
atrial refractory period
The programmed time after an atrial event during which the atrial sensing circuit is temporarily disabled.
automatic capture verification
A device feature that automatically adjusts pacing output to maintain capture while optimizing battery life.
battery depletion
The gradual exhaustion of a cardiac device's power source, indicated by specific voltage thresholds and device behaviors...
biocompatibility testing
Required laboratory evaluation of device materials to ensure they do not cause adverse biological reactions when implant...
bipolar lead
A cardiac lead with both positive and negative electrodes located at the distal tip within the heart.
blanking period
A programmed interval during which the device ignores electrical signals to prevent inappropriate sensing.
brady-tachy syndrome
A cardiac condition characterized by alternating periods of slow and fast heart rhythms, often requiring dual-chamber pa...
capture failure
The inability of a pacing pulse to initiate myocardial depolarization despite adequate electrical stimulation.
capture threshold
The minimum electrical energy required to consistently stimulate myocardial contraction through a pacing lead.
chronaxie
The minimum pulse width required to achieve capture at twice the rheobase voltage.
CIED
Umbrella term for implanted cardiac devices including pacemakers, ICDs, and CRT devices used in medical documentation.
conducted atrial fibrillation
Atrial fibrillation with atrioventricular conduction that may be sensed by a pacemaker's ventricular lead.
conductive lead fracture
Break in the electrical conductor within a pacing lead that maintains structural integrity but loses electrical continui...
conductor coil
Wound metal wire within cardiac leads that carries electrical signals between the pulse generator and heart tissue.
CRM system
Cardiac Rhythm Management system encompassing all implantable cardiac devices including pacemakers, ICDs, and CRT device...
CRT-D
A combination device that provides cardiac resynchronization therapy and defibrillation capabilities for heart failure p...
CRT-P device
A cardiac resynchronization therapy device that provides biventricular pacing without defibrillation capability.
DDD pacing
A dual-chamber pacing mode that can pace and sense both atria and ventricles with dual response capability.
defibrillation threshold
The minimum energy required to successfully terminate ventricular fibrillation, typically tested during ICD implantation...