Cardiac Device Manufacturing Glossary
100 terms total — 24 showing — Last updated 15 Sep 2026
NASPE/BPEG code
A five-letter coding system used to describe pacemaker programming and functionality.
PMI submission
A premarket investigation submission to regulatory authorities for approval to conduct clinical studies of cardiac devic...
pocket hematoma
Blood accumulation in the surgical pocket created for device implantation, a common post-operative complication.
pocket revision
Surgical procedure to modify or repair the implant pocket without device replacement, requiring specific procedural codi...
post-shock pacing
Temporary high-output pacing delivered immediately after defibrillation to ensure adequate heart rhythm until normal fun...
PPI
Post-pacing interval; the time from a paced ventricular beat to the next intrinsic atrial activity during tachycardia.
pulse generator
The main body of an implantable cardiac device containing the battery, circuitry, and control mechanisms.
QRS synchronous pacing
A pacing mode where ventricular stimuli are delivered in synchrony with intrinsic QRS complexes to maintain cardiac outp...
quadripolar lead
Cardiac resynchronization lead with four electrodes enabling multiple pacing configurations and improved electrical perf...
R-wave sensing
A pacemaker's ability to detect the natural electrical activity of the ventricles during heartbeats.
rate drop response
A pacemaker algorithm that detects sudden heart rate decreases and responds with temporary rate-responsive pacing.
rate-responsive pacing
A pacing feature that automatically adjusts heart rate based on physiological sensors detecting patient activity or meta...
remote monitoring alert
Automated notification from home monitoring systems indicating device malfunction or clinical events requiring physician...
sensing threshold
Minimum signal amplitude required for the device to detect intrinsic cardiac electrical activity, measured during device...
sensing vector
The electrical pathway between electrodes used by a cardiac device to detect intrinsic cardiac activity.
shock coil
The high-energy electrode component of a defibrillation lead designed to deliver cardioversion or defibrillation therapy...
shock impedance
Electrical resistance measured across defibrillation leads during high-energy therapy delivery, affecting shock efficacy...
shock impedance vector
Electrical resistance measurement along the specific pathway used for defibrillation energy delivery in ICD systems.
shock vector
The electrical pathway between defibrillation electrodes through which high-energy current flows during shock delivery.
steroid-eluting lead
A pacing lead that releases anti-inflammatory medication at the electrode-tissue interface to minimize fibrosis and main...
subcutaneous ICD
Defibrillator implanted under the skin without transvenous leads, requiring different editorial considerations for devic...
telemetry
Wireless communication between an implanted cardiac device and external monitoring or programming equipment.
tined lead
A pacemaker lead with flexible plastic projections designed to passively anchor the electrode in cardiac tissue.
unipolar lead
A cardiac lead configuration with one electrode at the tip, using the pulse generator case as the return electrode.
ventricular safety pacing
A safety feature that delivers a ventricular stimulus after detecting a signal in the post-atrial ventricular safety per...